Test ID OLIG Oligoclonal Banding, Serum and Spinal Fluid

Useful For

Diagnosis of multiple sclerosis; especially useful in patients with equivocal clinical presentation and radiological findings

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

CSF
Serum


Specimen Required


Both serum and spinal fluid are required. Spinal fluid must be obtained within 7 days of serum collection.

 

Specimen Type: Serum

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions:

1. Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.

2. Label specimen as serum.

 

Specimen Type: Spinal fluid

Container/Tube: Sterile vial

Specimen Volume: 0.5 mL

Collection Instructions: Label specimen as spinal fluid.


Specimen Stability Information

Specimen Type Temperature Time
CSF Refrigerated (preferred) 14 days
  Ambient  14 days
  Frozen  14 days
Serum Refrigerated (preferred) 14 days
  Ambient  14 days
  Frozen  14 days

Reference Values

CSF Oligoclonal Bands Interpretation: <2 bands

Day(s) Performed

Monday through Friday

CPT Code Information

83916 x 2

Report Available

4 to 7 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Secondary ID

8017