Test ID HGUCR Mercury/Creatinine Ratio, Random, Urine
Specimen Required
Patient Preparation:
1. For 48 hours before collection, patient should not eat seafood.
2. High concentrations of gadolinium and iodine are known to potentially interfere with most inductively coupled plasma mass spectrometry-based metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies: Urine Tubes, 10 mL (T068)
Collection Container/Tube: Clean, plastic urine container with no metal cap or glued insert
Submission Container/Tube: Plastic, 10-mL urine tube or clean, plastic aliquot container with no metal cap or glued insert
Specimen Volume: 3 mL
Collection Instructions:
1. Collect a random urine specimen.
2. See Metals Analysis Specimen Collection and Transport for complete instructions.
Secondary ID
608907Useful For
Detecting mercury toxicity, a toxic heavy metal, using random urine specimens
Special Instructions
Specimen Type
UrineSpecimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Urine | Refrigerated (preferred) | 7 days |
| Frozen | 7 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
MERCURY/CREATININE:
<18 years: Not established
≥18 years: <2 mcg/g creatinine
CREATININE:
<18 years: Not established
≥18 years: 16-326 mg/dL
Performing Laboratory
Mayo Clinic Laboratories in Rochester
CPT Code Information
83825
82570
Day(s) Performed
Monday through Friday