Sign in →

Test ID DTABS Diphtheria/Tetanus Antibody Panel, Serum

Useful For

Assessing antibody response to tetanus and diphtheria toxoid vaccines, which should be performed at least 3 weeks after immunization

 

Aiding in the evaluation of immunodeficiency

 

This test should not be used to diagnose tetanus infection

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL Serum

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 30 days
  Frozen  30 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject
Heat-inactivated specimen Reject

Reference Values

DIPHTHERIA TOXOID IgG ANTIBODY

Vaccinated: Positive (≥0.01 IU/mL)

Unvaccinated: Negative (<0.01 IU/mL)

Reference values apply to all ages.

 

TETANUS TOXOID IgG ANTIBODY

Vaccinated: Positive (≥0.01 IU/mL)

Unvaccinated: Negative (<0.01 IU/mL)

Reference values apply to all ages.

Day(s) Performed

Monday through Friday

Report Available

Same day/1 to 4 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86317 x 2

Forms

If not ordering electronically, complete, print, and send Infectious Disease Serology Test Request (T916) with the specimen.

Secondary ID

36670