Test ID DIA Diazepam and Metabolites, Serum
Useful For
Assessing compliance
Monitoring for appropriate therapeutic level
Assessing diazepam toxicity
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Specimen Type
Serum RedSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Red top (Serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum Red | Refrigerated (preferred) | 28 days |
| Ambient | 28 days | |
| Frozen | 28 days |
Reference Values
Therapeutic concentrations
Diazepam: Not established
Diazepam and Nordiazepam: 100-2,500 ng/mL
Cutoff concentrations by liquid chromatography tandem mass spectrometry:
Diazepam: 10 ng/mL
Nordiazepam: 10 ng/mL
Oxazepam: 10 ng/mL
Temazepam: 10 ng/mL
Day(s) Performed
Wednesday
CPT Code Information
80299
Report Available
3 to 7 daysReject Due To
| Gross hemolysis | OK |
| Gross lipemia | OK |
| Gross icterus | OK |
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.